Power Post™ 1-Zone Alarm Panel - Installation Instructions
Installation of the Alarm Panel
7. Plug the alarm panel power supply into a standard wall outlet or
receptacle (120VAC, 50/60 Hz), and then plug the quick connect
of the power supply cord into the incoming power receptacle of
the alarm panel. The green power LED should illuminate (solid)
when powered (Fig. 10).
Testing the Alarm Panel
1a. Test the alarm panel by pressing and holding the alarm test
pushbutton (Fig. 11). The alarm LED should illuminate (solid),
buzzer should annunciate (solid), and the auxiliary contacts
should activate. Press the alarm silence pushbutton and the buzzer
should silence while the alarm LED remains on. After the alarm
test pushbutton is released, the alarm panel will auto reset for the
next alarm cycle. Test product weekly to ensure system integrity.
1b. Test the alarm panel by activating the Power Post™ system
auxiliary contacts, alarm sensor(s) (Fig. 12), or follow the testing
steps of the Power Post™ system instructions. The Power Post™
septic alarm panel alarm LED should illuminate (solid), buzzer
should annunciate (solid), and auxiliary contacts should activate.
Press the alarm silence pushbutton and the buzzer should silence
while the alarm LED remains on. After the Power Post™ system
auxiliary contacts, alarm sensor(s), or testing procedure are
deactivated, the Power Post™ septic alarm panel will auto
reset for the next alarm cycle. Test product weekly to ensure
system integrity.
Note: If multiple sensors are used, perform a test for each sensor
connected to the alarm panel to ensure complete system operation.