Ⅶ.Wire Circuit Diagram
Wire Circuit Diagram
Applicable model: SWBC-13.5H-B
AIR SOURCE HEAT PUMP WIRING DIAGRAM
COMPRESSOR
CM
C
S
R
15K 2W
N
COMP-R
START
CON
KM-6
N
C B A
CN1
Y/G
L N
TO POWER SUPPLY
Transformer
Applicable model:
AIR SOURCE HEAT PUMP WIRING DIAGRAM
R
S
T
C B A
N
CN1
N-LINKER
Cn5
N
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9
TH1 TH2 TH3 TH4 TH5 TH6 TH7
2
2
2
2
T3
T4
T1
T2
SWBC-19.5H-B-S
AC contactor
Compressor
2
1
R
3
2
S
CM
5
6
T
A1
A2
N-LINKER
Cn5
N
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 OUT9
TH1 TH2 TH3 TH4 TH5 TH6 TH7
2
2
2
2
2
T5
T3
T4
T1
T2
FAN MOTOR
FM1
CN4
5
COM
CN2
CN3
2
2
4
T5
T6
Electronic
Wire
Expansion
Controller
Valve
FAN MOTOR
FM1
FM2
IN1
IN2
IN3
IN4
CN4
IN5
5
IN6
IN7
COM
CN2
CN3
2
4
T6
Electronic
Wire
Expansion
Controller
Valve
11
7
TO AC CONTACTOR
6
OF E-HEATER
5
TO AC CONTACTOR
4
OF WATER PUMP
3
2
S2
1
S1
COM-LINKER
HP-SW
IN1
LP-SW
IN2
FLOW-SW
IN3
IN4
IN5
IN6
IN7
Tank temp sensor
T1
T2
Ambient temp sensor
Coil temp sensor
T3
Exhaust temp sensor
T4
Suction temp sensor
T5
Water inlet temp sensor
T6
S1 Second set point
S2 Long distance demand for heating
7
TO AC CONTACTOR
OF E-HEATER
6
5
TO AC CONTACTOR
4
OF WATER PUMP
3
2
S2
1
S1
COM-LINKER
HP-SW
LP-SW
FLOW-SW
Tank temp sensor
T1
T2
Ambient temp sensor
T3
Coil temp sensor
Exhaust temp sensor
T4
Suction temp sensor
T5
Water inlet temp sensor
T6
S1 Second set point
S2 Long distance demand for heating
Water heater