18. Always use an approved cable extension suitable for the power rating of
this pump (see specifications), the conductor size should also be at least
the same size as that on the pump, or larger. When using a cable reel,
always unwind the cable completely.
19. Keep children and bystanders away while operating the pump.
Additionally, please keep these instructions in a safe place for future reference.
ELECTRICAL CONNECTIONS
All models EXCEPT HSE301A, 361A & HSEC651A should have their mains lead
connected to a standard 230 volt (50Hz) electrical supply through an
approved plug or a suitably fused isolator switch. We recommend that these
pumps be fitted with a Residual Current Device (RCD).
NOTE: This is mandatory when pump is used for pumping swimming pools.
Models HSE301, 361 & HSEC651A must be connected to a protected 110V
supply, through a suitably approved connector. On no account must a 230V,
13amp plug be used.
NOTE: If a portable 110V transformer is used, make sure it has a rated
capacity sufficient to take the load of the pump.
In the event that the pump is hard-wired into the electrical system, it must be
carried out in accordance with IEE regulations.
If used for draining swimming pools or ponds, the pump MUST be fitted with a
Residual Current Device (RCD), with a rated residual operating current of no
greater than 30mA.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
As the colours of the flexible cable of this appliance may not correspond with
the coloured markings identifying terminals in your plug proceed as follows:
• Connect GREEN & YELLOW coloured cord to plug terminal marked
with a letter "E" or Earth symbol "
& YELLOW.
• Connect BROWN cord to terminal marked with a letter "L" or
coloured RED.
• Connect BLUE cord to terminal marked with a letter "N" or coloured
BLACK.
Green & Yellow - Earth
Blue - Neutral
Brown - Live
" or coloured GREEN or GREEN