ABBINA EM 620 IX Manuale di istruzioni - Pagina 6
Sfoglia online o scarica il pdf Manuale di istruzioni per Piano cottura ABBINA EM 620 IX. ABBINA EM 620 IX 16. Cooking hobs vitroceramic
Instructions for the installer
Installation
GB
These Instrnctions are for the qualified technician, as a
guide to the installation, adjustment and maintenance,
according to the laws and standards in force. Any of these
operations must always be canied out when the appliance
has been disconnected from the electric system.
Positioning (Fig. 4)
The appliance can be fitted into a working area as
illustrated on the figure. Apply the seal supplied over the
whole perimeter of the working area.
Electrical connection (Fig. 5)
Prior io carrying out the electrical connection, please ensure that:
- the plant characteristics are such as to follow what is indicated
on the matrix plate placed at the bottom of the working area;
- that the plant is fitted with an efficient earth connection,
following the standards and law provisions in force.
The earth connection is compulsory in terms of the law.
Should there be no cable andlor plug on the equipment, use
suitable absorption material for the working temperature as
well, as indicated on the matrix plate. Under no circumstance
must the cable reach a temperature above 50°C of the
ambient temperature. lf connecting directly to the mains
power supply, fit a multi-pole switch of a suitable size for the
rated capacity with a clearance distance which completely
disconnects the power line under overvoltage category
III conditions, consistently with the rules of installation (the
yellow/green earth wire must not be interrupted).
The plug or omnipolar switch must be easily reached on the
installed equipment.
V
single-circuit radiant
single-circuit radiant
~ 230 V
double circuit radiant
double circuit oval radiant
HEATING ELEMENTS
TYPE
Ø 210/120-100-80
N.B.: - The manufacturers dedine any responsibility in
the event of non-compliance with what is described
above and the accident prevention norms not being
respected and followed.
To avoid all risk, if the power cable becomes damaged,
it must only be replaced by the manufacturer, by
an authorised service centre, or by a qualified
electrician.
Fig.5
* Considering contemporaneity factor
W
Ø 145
1200
Ø 180
1700
2100
170x265
2200-2400
6
H05RR-F3x2.5*
H05RR-F4x2.5
H05RR-F4x2.5
H05RR-F5x1.5
REGULATION
energy regulator
energy regulator
energy regulator
energy regulator
0+11
0+11
0÷11
0÷11