CAME BPT Agata C200 UK Manuale di installazione - Pagina 5
Sfoglia online o scarica il pdf Manuale di installazione per Sistema interfonico CAME BPT Agata C200 UK. CAME BPT Agata C200 UK 16.

A/200N
Description
A/200N guarantees the power supply to the HPC/1 entry panel
and a maximum of 20 front plates with 6 buttons HPP/6.
It is provided with the following functions:
- 2 two-tone call notes for two entry panels (or for additional
call, e.g. from front door).
- Power supply and control for solenoid lock (12 Vac, 1 A) via a
relay (inside the device) controlled by a timer, adjustable from 2
to 15 seconds using the potentiometer P11.
- Call generator: 2 types of two-tone notes (up to 3 internal
receivers can be connected in parallel on the same call). The
equipment can be powered at 12 VDC, for example by a battery
or continuity group (terminals +B and 5).
The equipment does not include a battery protection device.
105
105
105
105
A
A
43,5
7,5
57
43,5
7,5
57
B
B
64,5
64,5
Function of terminals and links
Terminal board A 1
Network
Terminal board B 1
+B
12 VDC input (*)
5
Ground
21
11 VDC output
8
Common call output 1
8A
Common call output 2
11
Audio from entry panel
12
Audio to entry panel
23
–
14 Vac output
16
+
NO
Normally open
C
Common
1
NC
Normally closed
(*) The device is electronically protected against overloads and
short circuits.
Terminal board C 1
5
Ground
8
Audio to internal receiver
9
Audio to internal receiver
Technical data
Type
50÷60 Hz (VAC) power supply
Power consumption (VA)
Output voltages at 11 VDC (mA)
Output voltages at 14 VAC (mA)
Peak output voltages (mA)
Operating output voltages (mA)
Storage temperature (°C)
Operating temperature (°C)
IP Rating
relay contacts
A/200N
230
34
150
650
300
650 (1A)
-25 ÷ +70
0 ÷ +35
IP30