CAME BPT Agata C200 UK Manual de instalação - Página 5

Procurar online ou descarregar pdf Manual de instalação para Sistema de intercomunicação CAME BPT Agata C200 UK. CAME BPT Agata C200 UK 16 páginas.

CAME BPT Agata C200 UK Manual de instalação
A/200N
Description
A/200N guarantees the power supply to the HPC/1 entry panel
and a maximum of 20 front plates with 6 buttons HPP/6.
It is provided with the following functions:
- 2 two-tone call notes for two entry panels (or for additional
call, e.g. from front door).
- Power supply and control for solenoid lock (12 Vac, 1 A) via a
relay (inside the device) controlled by a timer, adjustable from 2
to 15 seconds using the potentiometer P11.
- Call generator: 2 types of two-tone notes (up to 3 internal
receivers can be connected in parallel on the same call). The
equipment can be powered at 12 VDC, for example by a battery
or continuity group (terminals +B and 5).
The equipment does not include a battery protection device.
105
105
105
105
A
A
43,5
7,5
57
43,5
7,5
57
B
B
64,5
64,5
Function of terminals and links
Terminal board A 1
Network
Terminal board B 1
+B
12 VDC input (*)
5
Ground
21
11 VDC output
8
Common call output 1
8A
Common call output 2
11
Audio from entry panel
12
Audio to entry panel
23
14 Vac output
16
+
NO
Normally open
C
Common
1
NC
Normally closed
(*) The device is electronically protected against overloads and
short circuits.
Terminal board C 1
5
Ground
8
Audio to internal receiver
9
Audio to internal receiver
Technical data
Type
50÷60 Hz (VAC) power supply
Power consumption (VA)
Output voltages at 11 VDC (mA)
Output voltages at 14 VAC (mA)
Peak output voltages (mA)
Operating output voltages (mA)
Storage temperature (°C)
Operating temperature (°C)
IP Rating
relay contacts
A/200N
230
34
150
650
300
650 (1A)
-25 ÷ +70
0 ÷ +35
IP30