3. Application
The KINAX N702-INOX HART is a very robust, absolute inclina-
tion transmitter. It is particularly suited for harsh environments
due to it is high mechanical strength and the hermetically
sealed stainless steel housing. It makes it resistant against
aggressive media such as sea water and detergent.
The very simple assembly by the synchro fl ange or mounting
plate, the highly fl exible 2-pole signal line, the free parame-
terisation via HART interface offers maximum installation
fl exibility.
4. Main features
• Robust inclination transmitter suitable for fi eld applications
• Hermetically sealed stainless-steel INOX AiSi 316Ti
(1.4571) housing with a protection class of IP68 and
IP69K
• Resistant to aggressive media such as sea waterand
detergent
• Steadfast to high mechanical loads
• 4 ... 20 mA, 2-Draht-Technik, HART compatible
• Simple parameterization via standard Common Practice
Commands without additional DD
5. Technical data
5.1 General
Measured quantity:
Measuring principle:
Pendulum damping:
5.2 Measuring input
Measuring range:
Inclination angle:
Sense of rotation:
12
Tilt angle
Magnetic, one-dimensional
inclination transmitter with hall
sensor and oil-damped pendulum
system, hermetically sealed, con-
tact free, freely rotatable without
stops
N
oil damped pendulum
C
S
X axis
by oil fi lling
Programmable between 0 ... 360°
Set to -180 ... 179.99°
I [mA]
20.5
20.0
4.0
3.9
-180
180
0°
Utilisation area
Adjustable for rotation clockwise or
counter-clockwise
5.3 Measuring output
Power supply:
Output signal I
:
A
Standard range:
Interface:
Current consumption:
Fault current:
External resistance:
5.4 Accuracy
Basic accuracy:
Resolution:
Transient response:
Infl uence of temperature
output current
(–30°...+70°C):
[-22 ... +158°F]
5.5 Installation data
Housing:
Mounting position:
Electrical connection:
Weight:
5.6 Regulations
Spurious radiation:
Immunity:
Test voltage:
Water column:
Housing protection:
5.7 Environmental condition
Climatic rating:
Vibration resistance:
Shock resistance:
Transportation and
storage temperature:
[°]
8 ... 33 VDC
Load-independent DC current,
proportional to the inclination
4...20 mA, 2-wire connection
protection against wrong polarity
HART compatible
< 22 mA
> 21.5mA (nominal 21.7 mA) and
< 3.5 mA (nominal 3.3 mA)
H [V]-8V
R
[kΩ] =
ext max.
I
[mA]
A
H = Power supply
I
= Output signal end value
A
± 0.2 ° (at +25 °C)
14 bit
by 25° tils < 1 sec.
0.1° / 10K (<100°)
up to 0.2° / 10K (>100°)
Stainless-steel INOX AiSi 316Ti
(1.4571)
Perpendicular to the measurement
object
highly fl exible shielded 2-pin signal
line with PUR steath
approx. 1.1 kg [35.366 oz]
EN 61 000-6-4
EN 61 000-6-2
500 Veff, 50 Hz, 1 min.
30 m
IP 68 acc. to EN 60 529
Temperature – 30° to + 70° C
[-22 ... +158 °F]
2
40 m/s
/ 10 ... 500 Hz
acc. IEC 60068-2-6
300 m/s
2
/ 18 ms
acc. EN 60068-2-27
– 30° to + 70° C [-22 ... +158 °F]