ABC PROIZVOD Concept 2 mini air Istruzioni tecniche - Pagina 7

Sfoglia online o scarica il pdf Istruzioni tecniche per Elettrodomestici da cucina ABC PROIZVOD Concept 2 mini air. ABC PROIZVOD Concept 2 mini air 16. Central heating cookers

ABC PROIZVOD Concept 2 mini air Istruzioni tecniche
5. PLACEMENT / INSTALLATION
Design, placement and central heating installation is mandatory to be done by a qualified person.
In case of poorly designed system and possible defects in installation by mentioned person,
which in turn may cause incorrect cooker functionality, solely the installer of heating system, not
the manufacturer, representative or retailer of the cooker, bears both complete material
responsibility and unexpected expenses.
The cooker may be placed in the kitchen or some other suitable area, under the condition that a
non-flammable base, sufficient manipulation area, room ventilation and suitable chimney are
provided.
When installing the cooker, take care about the following:
а) Furniture and objects next to the cooker must not be made of flammable materials, otherwise
their distance from the cooker has to be min. 20 cm.
b) Under no circumstances can the shelves or similar wooden furniture be placed under the
cooker hob
c) The wall which is in contact with the back of the cooker has to be made of a heat-resistant
material
d) Do not place curtains directly behind the cooker, when placing them laterally, they should be
placed as far as possible
e) Flammable materials, f.e. door frames, wallpapers have to be at least 20 mm away from smoke
tubes. This distance may be reduced if appropriate thermal insulation is installed around smoke
tubes.
f) Place the cooker in horizontal position or lift the back of it slightly (2-4 mm).
5.2. CONNECTION TO CHIMNEY
As an essential component of central heating system, the chimney has to have an appropriate
cross section, and to be duly installed, correctly placed above the roof and insulated (F.4).
Determination of the size and check of the existing chimney is performed by the designer
of central heating utility based on the cooker capacity, fuel type of required drought for selected
cooker.
The cooker reaches the declared power only in case of appropriate size of the chimney.
All smoke tube joints from the cooker to the chimney have to be properly sealed. F.3.
The chimney needs to be duly placed above the roof as per the instructions presented in F.4.
Avoid the placement of chimney caps, especially if with lateral blinds. In case of possible
placement of a chimney cap, act as recommended in F. 4. .
6