Alula RE605 Manuale di avvio rapido

Sfoglia online o scarica il pdf Manuale di avvio rapido per Regolatore di temperatura Alula RE605. Alula RE605 2. Temperature sensor connect+ compatible
Anche per Alula RE605: Manuale di avvio rapido (2 pagine)

Alula RE605 Manuale di avvio rapido
The RE605 Temp Sensor
overheat conditions. The sensor will alarm when the
temperature trip points are reached.
Features
• Indicates freeze and overheat warnings
• Industry-leading wireless range and battery life
• Secure encrypted wireless transmissions
• 5-year warranty
Enroll
by placing the panel into wireless enrollment mode
and then sending an enrollment signal from the sensor.
Alternatively, the sensor can be enrolled by scanning
its bar code using the Connect+ Installer App or by
entering its 8-character serial number on the interactive
service provider's web portal.
Options for sending an Enrollment Signal
• Remove the battery tab, OR
• Remove the cover to trip tamper
Install
by mounting the sensor in the desired location
using two #4 or #6 screws. An optional cover-securing
screw is included. Alternatively, the sensor can also be
installed using 3M VHB tape.
Freeze or Heat alarms
temperature trip points are reached.
Temperature Trip Points
• Heat alarms when over 100°F (38°C)
• Heat restores when under 97°F (36°C)
• Freeze alarms when under 45°F (7°C)
• Freeze restores when over 48°F (9°C)
Use the panel installation guide to verify proper system setup.
RE605 Temperature Sensor
Connect+
is used to detect freeze and
are transmitted when the
Compatible
Mounting Screw Holes
Cover-Securing Screw Hole
I