Activating the relay does not unlock the door.
When you scan a valid ticket or manually activate the relay on the Device Tests screen, the door does not unlock.
Potential Cause
The relay is not wired correctly.
The door strike is not receiving power. (IntraQ-X provides
power.)
The 12V fuse is blown (Amanda DC boards only).
The door strike is not receiving power. (External power
supply.)
Page 18
For Assistance: [email protected] +1 (909) 591-8431
IntraQ-X Installtion Guide Version 2.0
IntraQ-X Installtion Guide Version 2.0
Solution
Check the diagrams in the
Door Lock/Strike Wiring
section on pages 4.
Verify the relay is wired correctly for the desired
configuration.
Verify the door strike does not draw more than 12 VDC
(600 W) power.
Verify the relay, POE splitter, and door strike wires are
properly connected.
Check the 12V fuse for continuity.
Replace the 12V fuse.
Verify the relay, power supply, and door strike wires are
properly connected.