SET-UP & OPERATION
1. Unpack the compressor and locate the
remote power cord.
2. Plug the power cord into the receptacle on
the outside of the unit and then into a
grounded power outlet.
3. To activate the AA-98 compressor, flip the
power switch to the on (I) position. Once
powered, the compressor will start and stop
automatically to maintain pressure. The
pressure switch is factory adjusted to
properly start and stop. The cooling fan will
operate continuously.
4. After plugging the compressor in and turning
it on, let the compressor run until it stops,
indicating full pressure.
5. Locate the 1/4" quick disconnect air outlet
and pressure gauge on the end of the
compressor case. Connect a 1/4" male
coupling from your equipment to the air
output fitting. The pressure gauge indicates
pressure in the air storage tanks and gives a
visual indication that the compressor is
maintaining pressure properly.
6. The AA-98 compressor will cycle on and off
as air is consumed during use. This is
normal for operation. Turn compressor off if
it is not to be used for extended periods of
time.
7. To turn the compressor off, flip the power
switch to the off (O) position.
3
PRESSURE
GAUGE
POWER
SWITCH
POWER CORD
RECEPTACLE
10A CIRCUIT
BREAKERS
AIR
OUTLET