Cloud 36 Manuale di installazione e funzionamento - Pagina 13
Sfoglia online o scarica il pdf Manuale di installazione e funzionamento per Amplificatore Cloud 36. Cloud 36 14. 36/50 2 zone integrated mixer amplifier
12
28
Technical Specifications
Line inputs
Frequency Response
Distortion
Sensitivity
Input Gain Control
Input Impedance
Headroom
Noise
Equalisation
Microphone Inputs
Frequency Response
Distortion
Gain Range
Input Impedance
Common mode rejection
Headroom
Noise
Equalisation
Outputs
Low Impedance Outputs – 4 Ohm Load/s
Low Impedance Outputs – 8 Ohm Load/s
100V Line Output
70V Line Output
Protection
Cooling
29
General Specifications
Power input
Fuse rating
Fuse type
Dimensions
Weight 36/50
This product conforms to the following European EMC Standards:
BS EN 55103-1:1997
BS EN 55103-2:1997
This product has been tested for use in commercial and light industrial environments. If the equipment
is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded.
The product conforms to the following European electrical safety standard.
BS EN 60065:1998
06/12/02 V5.0
20Hz-20kHz ±0.5dB
<0.05% 20Hz -20kHz
195mV (-12dBu) to 2.0V (+8dBu)
20dB range
47kΩ
>20dB
-90dB A weighted (0dB gain)
HF: ±10dB/10kHz
100Hz / -3dB(filter) 20kHz ±0.5dB
<0.05% 20Hz-20kHz
0dB-60dB
>2kΩ (balanced)
>70dB 1kHz
>20dB
-126dB EIN 22Hz-22kHz (150Ω)
HF: ±10dB/5kHz
1ch driven 60 watts, 2ch driven 52watts,
3ch driven 45watts
1ch driven 37 watts, 2ch driven 34watts,
3ch driven 30watts
100 volts balanced – 250Ω min load
(optional module)
70 volts balanced – 125Ω min load
(optional module)
VI Limiting, DC Offset, Thermal & switch-
on delay
Convection
230V ±5% (115V ±5% available)
230V – T3.15A H
115V – T6.3A H
20mm x 5mm 250V
482.60mm x 88.00mm(2U) x 300.00mm deep (+ con)
6.70kg net
36/50: Installation and Operation Manual
LF: ±10dB/50Hz
LF: ±10dB/100Hz