ASI 0362 Istruzioni per l'installazione - Pagina 2
Sfoglia online o scarica il pdf Istruzioni per l'installazione per Dispenser ASI 0362. ASI 0362 2.
7. OPERATION INSTRUCTIONS
A. Service Instructions
1.Open housing with included security key previously retained.
2.Open cover on battery compartment, remove battery box and unplug cable;
install four (4) new Alkaline Type AA 1.5V batteries with correct polarity
(note the +/- indication, fig. 7) to obtain 6.0V DC ± 10% at the plug.
3.Reinstall battery box (note plug polarity tab) and close compartment cover.
4.Obtain a disposable soap cartridge (800ml) or remove, clean out and refill
(fig. 8) the included reusable soap reservoir with the correct viscosity liquid
soap (ensure that soap container cover is closed and air vent hole is open
and nozzle is not clogged and that soap container is clean (no spill-over)
and not leaking) and install either in the dispenser. Make sure the nozzle
flange is below the housing cradle rib to stretch the valve tube.
5.Make sure to latch the cradle gate.
6.Observe that the LED is lit blue and then flashes three (3) times indicating proper
operation "stand-by" condition and battery charge level (push up the cover safety interlock
switch (blue stem) on bottom to click and hold it).
7.Close the housing cover and lock it with the included security key previously retained.
8.Trigger the sensor with hands or a towel to check proper soap dispensing cycle (fig. 9).
VENT HOLE
TAB
fig. 7
Type AA 1.5V x 4
fig. 8
B. User's Instructions
1.Place hand below the dispenser spout within the sensing range. The dispenser will
automatically release the preset amount of liquid soap from the nozzle spout.
2.Obtain additional soap by withdrawing hand and then again placing hand below the
dispenser spout within the sensing range.
8. SENSING RANGE
Sensing is automatically controlled to set the appropriate distance for the triggering zone.
This is based upon mounting height above the counter or floor and the ambient and reflected
lighting conditions. There are no user adjustable controls for this feature.
It is important to observe the guidelines in Section 4 (on reverse side of these instructions) and
install unit above the minimum distance noted for each type of field condition.
If lighting conditions change during the life of the installation the unit will automatically readjust
itself to accommodate the new environment with no intervention by owner.
Countertop reflective quality changes constitute a new environment condition and may require
dispenser relocation to just above the appropriate minimum height as noted in Section 4 (on
reverse side of these instructions).
6. INSTALLATION STEPS CHECK
1.Check to ensure that dispenser is firmly attached to mounting surface.
2.Check to ensure that correct viscosity soap is filled into reservoir.
3.Check to ensure that soap container cover is closed and air vent hole is not blocked.
4.Check to ensure that soap container is clean (no spill-over) and not leaking.
5.Check to ensure that cradle gate is latched on valve tube (lift, push and press down to engage pins to latch or
unlatch in reverse operation).
6.Check to ensure that four (4) new Alkaline Type AA batteries are installed with correct polarity (note the +/- indication,
fig. 7, and below, typical).
7.Check to ensure that the battery box plug is properly engaged with the cable and the compartment door is closed.
8.Check to ensure that the LED is lit blue and then flashes three (3) times by pushing up the cover safety
interlock switch (blue stem) on bottom to click and hold it.
9.Check to ensure that the housing is properly locked and the security key is retained.
10.Check to ensure that the plastic nozzle cap was removed.
9.IMPORTANT NOTICE
1. Ensure no bright source is aimed or reflected at the
sensor from below.
2. Use fresh new liquid soap only and clean the soap
container properly before each re-fill. Deposits of old
soap will lead to malfunction and jamming.
3. Do not dilute liquid soap unless concentrate and do not
use soap containing abrasive. Observe indicated
viscosity factor of liquid soap.
fig. 9
4. Do not immerse the soap dispenser in water or clean it
RIB
under running water. This will lead to short circuit.
5. Should the dispenser be out of order and batteries have
been replaced, do not attempt any repair work. Call your
dealer for professional assistance.
11.TROUBLESHOOTING
Problem Symptom
No soap dispensed on hands
Battery LED indicator no flash
Low volume soap dispensed
Soap leaks at bottom of housing
AA (1.5V)
Caution : Batteries installed with incorrect polarity may cause malfunction.
10. BATTERY LOW INDICATION
With housing cover open and soap reservoir removed
(see Service Instructions) perform the following
diagnostic test:
1.Press and push up the cover safety interlock switch
(blue stem) on bottom to click and hold it.
2.Observe that the LED
three (3) times indicating proper operation "stand-by"
condition and battery charge level.
3.If LED continue
positive to replace the batteries.
Solution Diagnostic
Check soap qualities, properties and level in reservoir
Check sensor cover for dirt obscuring the lens
Check battery charge level
Check spout nozzle, cap air hole and valve tube for clogs
Check for reflected sensor signals jamming detector
Replace batteries
Remove soap container and wash out spout nozzle, cap air hole
and valve tube and replace with fresh new soap
Check if cradle gate is not properly latched
Check if valve tube is loose in cradle or cross-threaded
Check if valve tube cross-threaded onto bottom of reservoir or
reservoir is damaged/punctured
Check disposable soap cartridge for defects and/or replace
is lit blue and then flashes
s to flash blue the indication i
s