ASI JD MACDONALD 10-20201-2 Istruzioni per l'uso e manuale delle parti - Pagina 3

Sfoglia online o scarica il pdf Istruzioni per l'uso e manuale delle parti per Asciugatrice ASI JD MACDONALD 10-20201-2. ASI JD MACDONALD 10-20201-2 15. High-speed hand dryer
Anche per ASI JD MACDONALD 10-20201-2: Installazione (2 pagine)

ASI JD MACDONALD 10-20201-2 Istruzioni per l'uso e manuale delle parti
Hand Dryer

Installation

See Installation Guide 1203270822
1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with
the current edition of the local wiring regulations code having jurisdiction. Installation requiring hard
wiring should be performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark
locations of eight (8) mounting holes and wire service entry at knockout (KO) location.
Note: For two or more dryers, dryers should be no closer than 24 inches (610 mm) on center.
3.
Use L-Key (supplied) to unlock security hex socket screw and withdraw filter access drawer.
4. a. Drill eight (8) holes at locations marked of Ø9/32" (Ø7) x 1-3/8" (35) deep if using wall anchors
supplied with unit (fig.1)
b.
Remove template and Insert eight (8) plastic anchors (supplied) into drilled holes (fig. 2).
Install supplied anchors flush with wall face, or install other fastening system suitable for wall
conditions (not supplied).
c. Attach base plate to wall by i
anchors (fig. 3).
inch (25) min. stud penetration. For masonry walls use expansion bolts or anchors for Ø1/4
inch (M6) screws to ensure penetration 1/4 inch (6) deeper than anchor. Shim if necessary to
ensure base plate is flat against wall.
5. a.
Hang the dryer on the base plate (fig. 4).
b. For in-wall (concealed) power supply -
Provide supply wire to KO location according to local code and attach securely to chassis at KO
with strain relief connector (supplied).
c. For Surface Mounted Conduit (exposed) power supply or using power cord (supplied) -
Provide appropriate conduit to entry location according to local code and attach securely to
chassis with correct strain relief connector (not supplied) or install unit on wall within PCRR to
duplex outlet.
d. Install locking screw (supplied) into wall plate through the hole at backplate center bottom. (fig. 5)
6. a. Connect hard wired power provided at KO location to terminal block behind cover panel (RH-bottom)
behind filter drawer. Turn on circuit breaker to initiate
A. Connect the live wire (colored Brown, Red or Black) to the terminal block marked "L".
B. Connect the neutral wire (colored Black, Blue, White or Grey) or connect the second live wire
(colored Red or Orange) to the terminal block marked "N".
C. Connect the ground wire to the terminal block marked "
be sleeved with green and yellow or green tubing. Colors of live and neutral wires depend on
voltage of supply service and requirements of Building and Electrical Code having jurisdiction.
b
. Connect power cord to initiate 'stand by- ready to operate' status.
7. Replace the filter access drawer, being careful to not over-tighten the security screw.
8. See separate sections for owner options on heater operation and air speed adjustment.
(fig. 1)
Operating Instructions and Parts Manual
Surface-mounted High-Speed hand dryer
nserting eight (8) screws (supplied) to fix backplate into plastic
For wood wall/studs use Ø1/4 inch (M6) screws at length that will ensure 1
Connections:
(fig. 2)
(fig. 3)
'stand by- ready to operate' status.
" . Bare grounding (earth) wires should
S
(fig. 4)
3
A S I J D M a c D o n a l d P t y. L t d .
www.asijdmacdonald.com.au
1800 023 441
SECURITY
SCREW
VIEW S
(fig. 5)
www.asijdmacdonald.com.au