ASI JD MACDONALD 10-20201-2 Istruzioni per l'uso e manuale delle parti - Pagina 4

Sfoglia online o scarica il pdf Istruzioni per l'uso e manuale delle parti per Asciugatrice ASI JD MACDONALD 10-20201-2. ASI JD MACDONALD 10-20201-2 15. High-speed hand dryer
Anche per ASI JD MACDONALD 10-20201-2: Installazione (2 pagine)

ASI JD MACDONALD 10-20201-2 Istruzioni per l'uso e manuale delle parti
Hand Dryer
General safety information
This product is intended
for installation by a qualified service person.
Select wire ga to suit unit model ratings.
Failure to properly ground
unit could result in severe electrical shock
and/or death.

Operation

1.
Put your hands into the opening.
Rub hands together to speed dry.
2.
Remove hands and dryer will stop
3.
automatically.
Dryer maintains operation for 1 second
4.
after last sensor activation to evaporate
droplets.
1.
2.
Patented
Cleaning and Maintenance
Periodic cleaning of the unit is recommended to ensure optimum performance.
Wipe the cover with a damp cloth and mild cleaning solution.
Do not Soak, Do not hose down.
Never use abrasives to clean the cover. Caustic chemicals may damage unit finish.
No internal parts need any regular cleaning.
Patented
Installation Kit Included (find in carton)
1. Self-Threading pan head screws №10 x 1-1/4" (M5 x 32) x 8 pcs
2. Plastic expansion anchor Ø9/32" x 1-3/8" (Ø7 x 35) x 8 pcs
Service Tools Included (with installation kit)
Security hex
wrench
Deep C-socket Wrench (for Cord Strain Relief Nut)
Operating Instructions and Parts Manual
Surface-mounted High-Speed hand dryer
3.
4 mm x 1 pc (5/32" pin-hex will work if tool is lost)
service breaker before installing or servicing.
with a 3-wire service. The ground wire must
be connected to the dryer's ground terminal.

Circuit Diagram

Supply:220-240VAC, 50/60Hz
L
N
G/Y
G
MO2 HE2
L
MO1 HE1
Transistor
Circuit Board Module
Power Switch
LED & SENSOR
See Separate Sections for Filter,
Ceramic Water Evaporator and
Drain Tray Maintenance
Please unpack the unit and check the quantity
of the tools and kit.
4
A S I J D M a c D o n a l d P t y. L t d .
www.asijdmacdonald.com.au
1800 023 441
Disconnect power at the
All units must be supplied
Red(110-120VAC)
Black
Black
N
VR1
FOR SENSOR
White (110-120VAC)
1 2 3 4
VR2
www.asijdmacdonald.com.au
FOR MOTOR