Cytech Comfort DM02 Manuale - Pagina 10

Sfoglia online o scarica il pdf Manuale per Apparecchiature di registrazione Cytech Comfort DM02. Cytech Comfort DM02 16. Door station interface

Comfort DM02 Door Station Interface
The connections between Comfort's DM02 and Fermax Door Stations are
as follows:
Fermax
1
2
3
4 and L+
6
Note that NO2 and COM2 are optional connections, NO1 and COM1 may
be used instead. They are used to trigger relays K1 and K2 so that the
electric lock is able to be activated via the "Open Door" and "Open Gate"
commands.
DM02
NO2
SPK OUT
GND, COM2
BELL
MIC IN
Remarks
Used in conjunction with 3 to
activate the electric lock.
Audio from indoor to outdoor
Common Ground (Shorted
with 1 to trigger electric lock)
Call wire, sends signal when
pushbutton is pressed.
Audio from outdoor to indoor
6