Cytech Comfort DM02 매뉴얼 - 페이지 10
{카테고리_이름} Cytech Comfort DM02에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cytech Comfort DM02 16 페이지. Door station interface
Comfort DM02 Door Station Interface
The connections between Comfort's DM02 and Fermax Door Stations are
as follows:
Fermax
1
2
3
4 and L+
6
Note that NO2 and COM2 are optional connections, NO1 and COM1 may
be used instead. They are used to trigger relays K1 and K2 so that the
electric lock is able to be activated via the "Open Door" and "Open Gate"
commands.
DM02
NO2
SPK OUT
GND, COM2
BELL
MIC IN
Remarks
Used in conjunction with 3 to
activate the electric lock.
Audio from indoor to outdoor
Common Ground (Shorted
with 1 to trigger electric lock)
Call wire, sends signal when
pushbutton is pressed.
Audio from outdoor to indoor
6