AMBIC EasiDoser Manuale di istruzioni per l'uso - Pagina 9
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Macchine agricole AMBIC EasiDoser. AMBIC EasiDoser 16.
Action
From Display 14
Press Button once
From Display 15
Press Button once
From Display 16
Press Button once
From Display 17
Press Button once
From Display 18
Press Button once
From Display 19
Press Button once
From Display 20
Press Button once
From Display 21
Press Button once
From Display 22
Press Button once
From Display 23
Press Button once
From Display 24
Press Button once
Ambic Equipment Ltd – EasiDoser™ Operating Notes
Display
Display Number 15
Pump 2 Mode
Manual Mode ←↑↓→
Display Number 16
Pump 2 Duration
00:15
Display Number 17
Pump 2 Start
Delay = 5s
Display Number 18
Pump 2 Inhibit
00:00
Display Number 19
Pump 2 Speed
= 80%
Display Number 20
Pump 2 Float
N/Open
Display Number 21
Change PIN Code
Display Number 22
Select Language
English
Display Number 23
Calibrate
Pump 1
Display Number 24
Calibrate
Pump 2
Display Number 25
Save
Configuration
Press buttons until correct pump mode
for Pump 2 is displayed. (Manual, Signal or
Direct)
Press
duration (run time) is displayed. Run time can
←↑↓→
be set from 00:00 seconds to 05:00 minutes.
Default setting: 00:15
Press buttons until correct pump Start
Delay is displayed. Pump start delay time can
←↑↓→
be set from 1 second to 60 seconds.
Default setting: 5s
Press
duration (run time) is displayed. Pump inhibit
time can be set from:
←↑↓→
00:00 seconds to 30:00 minutes.
Default setting: 00:00
Press buttons until correct pump Start
Delay is displayed. Pump speed can be set
←↑↓→
from 40% to 100%
Default setting : 80%
Press buttons until correct Float Switch
is displayed.
←↑↓→
Default setting: N/Open
To change the PIN code used to access
↑
certain MENU items.
0 ↓
(see Changing PIN)
Press button once to Enter PIN code to
↑
access Select Language screens.
←0→ ↓
(see Changing Language)
To check dispensing volume of Pump 1 press
↑
button once.
0 ↓
(see Calibration Method)
To check dispensing volume of Pump 2.
↑
(see Calibration Method)
0 ↓
Press button once.
Displays automatically changes to Display 2.
↑0
-9-
Comment /Action
buttons until correct pump
buttons until correct pump
ADE7500 v1.3 (16/03/18)