Ambient Recording ACD 201 Manuale - Pagina 11
Sfoglia online o scarica il pdf Manuale per Apparecchiature di registrazione Ambient Recording ACD 201. Ambient Recording ACD 201 20.
2.3.9 The Frame (FF) Digits
Display
24
25 23
Fps
24
25
Note:
The framerate displayed is an indication of the dipswitch setting and
cannot be changed by the cursor.
2.3.10 The ct and cd functions
The ct or cd function can be selected in the FF position.The slate must also
be in the generator /RTC mode.
Select ct
When Load is implemented the R T C is set from the generator
time and date.
Select cd
When Load is implemented the R T C is loaded from the current
display time and date. (Set manually)
Select Fps (Dipswitch value shown)
When Load is implemented only the generator is loaded with the
selected data.
2.3.11 Setting the generator
There are three settings of the dipswitches in which the generator is active.
A
B
C
In Generator
On power-up the generator starts counting from 00.00.00.00 .and the
userbits are 00.00.00.00. The Red LED blinks.
Go to set mode. (See 2.3)
Set user bits as above and move cursor to time frame.
Set time value and verify framerate in last 2 digit positions.
To LOAD press both buttons simultaneously till display runs.
Userbits can be loaded without changing time by selecting the
userbits and loading with the cursor in the userbit display.
In Generator / RTC Mode
On power-up the generator is loaded with the RTC time and date
values. The Green LED blinks.
The framerate is as selected by the dipswitches.
The values entered by the RTC will be overidden by a manual set as
above or by jamming from Ext TC.
29
2d
23.98
29.97
29.97
Drop
Frame
Generator Mode
Generator/ RTC Mode
Reader/ Generator Mode
Mode
30
3d
ct
30
30
set
Drop
RTC
Frame Gen. TC Manual Displ.
cd
set
RTC from