- ページ 15
ステレオシステム Flock Audio PATCHのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Flock Audio PATCH 20 ページ。
MULTIPLE UNIT SETUP
MULTIPLE UNIT ANALOG CONNECTIONS
When connecting multiple hardware units together for Multi-
Unit configurations, a user must choose which connections to
configure in order to send &/or receive analog audio signals
between multiple PATCH LT Hardware Units.
As shown in the example to the right, 2 PATCH LT Hardware
Units are connected with 8 Sends and 8 Returns. This
configuration example allows a user to Send 8 analog audio
signals from one PATCH LT #1 to PATCH LT #2 and return 8
analog audio signals to PATCH LT #1 (if required).
This is only an example of the possible Multi-Unit routing
configurations and is not restrictive of other user desired
configurations. Users may choose to have more or all sends
then equal returns.
The below example shows a simple PATCH APP Software view
of how a Multi-Unit Hardware setup would appear in the
PATCH APP when routing from PATCH LT #1 to PATCH LT #2
and back again. More information on multi-unit setups can be
found in the PATCH APP manual.
PATCH MANUAL
PATCH LT (#1)
W h e n D r a g g i n g +
Dropping a SEND "Pass"
into a signal flow digital
rack space that is empty,
PATCH LT (#2)
t h e PAT C H A P P w i l l
populate both SEND &
RECEIVE Digital Rack
Spaces with color-coded
outlined racks to allow
t h e u s e r t o e a s i l y
distinguish which PATCH
Series unit is which.
Multiple PATCH System Setup
(4) SEND/RETURN PASSES
15
(24 CHANNELS) ANALOG
PROCESSING HARDWARE
MULTIPLE UNIT SETUP