Flock Audio PATCH User Manual - Page 15
Browse online or download pdf User Manual for Stereo System Flock Audio PATCH. Flock Audio PATCH 20 pages.
MULTIPLE UNIT SETUP
MULTIPLE UNIT ANALOG CONNECTIONS
When connecting multiple hardware units together for Multi-
Unit configurations, a user must choose which connections to
configure in order to send &/or receive analog audio signals
between multiple PATCH LT Hardware Units.
As shown in the example to the right, 2 PATCH LT Hardware
Units are connected with 8 Sends and 8 Returns. This
configuration example allows a user to Send 8 analog audio
signals from one PATCH LT #1 to PATCH LT #2 and return 8
analog audio signals to PATCH LT #1 (if required).
This is only an example of the possible Multi-Unit routing
configurations and is not restrictive of other user desired
configurations. Users may choose to have more or all sends
then equal returns.
The below example shows a simple PATCH APP Software view
of how a Multi-Unit Hardware setup would appear in the
PATCH APP when routing from PATCH LT #1 to PATCH LT #2
and back again. More information on multi-unit setups can be
found in the PATCH APP manual.
PATCH MANUAL
PATCH LT (#1)
W h e n D r a g g i n g +
Dropping a SEND "Pass"
into a signal flow digital
rack space that is empty,
PATCH LT (#2)
t h e PAT C H A P P w i l l
populate both SEND &
RECEIVE Digital Rack
Spaces with color-coded
outlined racks to allow
t h e u s e r t o e a s i l y
distinguish which PATCH
Series unit is which.
Multiple PATCH System Setup
(4) SEND/RETURN PASSES
15
(24 CHANNELS) ANALOG
PROCESSING HARDWARE
MULTIPLE UNIT SETUP