10 Technical Data
BLS3000
Measuring element
Reed switch
Measuring ranges
L0 = max. 1000 mm, LM: see name plate
Display
4-digit 14-segment LED display, red, digit height 9 mm
Transistor switching outputs PNP
1 or 2 x NO/NC function (programmable), adjustable switching time delay
0 ... 50 s
Resolution
5 mm
Ambient temperature range
-20 ... +70 °C / -4 ... +158 °F
Media temperature range
-25 ... +80 °C / -13 ... +176 °F
Storage temperature range
-30 ... +80 °C / -22 ... +176 °F
Process connection
G ½" M, G ¾" M, G 1" M, M20x1,5 M, ½" NPT M, ¾" NPT M,
1" NPT M, 1¼" NPT M
2)
Protection system
/ class
IP65, IP67; UL-Type 1,4X,6 / III
Electrical connection
Plug M12x1 mm, 4/5/8-pin (depending on output code),
Power supply
15... 32 V DC /relay-output: 20-32 V DC
1)
Approvals
cULus
For further technical data and options please refer to the data sheets
1)
Conditions of use: 60°C max. ambient, power supply max. 28 V DC
2)
The stated ingress protection only applies when plugged in using mating connectors that have the appropriate
ingress protection
Operating and display elements/Dimensions
41 (1.598)
M12x1 Connector
hex 27
(1.063)
G1/2" Shown
17.80 (0.701)
12
Dimensions (example) in mm (inch)
1
2
Item 1: LEDs
AL
(red) – Alarm
S1
(red) – switching point 1
S2
(red) – switching point 2
Item 2: keys
For functions refer to chapter 7
"Programming" on page 5.

Operating Instructions ............................................................................................................ 2

 
1
Intended Applications ................................................................................................... 2
 
2
Safety Instructions ......................................................................................................... 3
 
3
Standards ....................................................................................................................... 3
 
4
Warranty/Guarantee ....................................................................................................... 3
 
5
Installation ...................................................................................................................... 3
 
6
Commissioning/Operation ............................................................................................ 5
 
O
7
Programming .................................................................................................................. 5
 
7.1
Parameters ............................................................................................................. 6
 
7.2
Menu Structure ....................................................................................................... 8
 
8
Maintenance/Cleaning ................................................................................................. 11
 
9
Decommissioning ........................................................................................................ 11
10
Technical Data ............................................................................................................... 12
Barksdale Inc.
3211 Fruitland Avenue
Los Angeles, CA 90058-0843
U.S.A.
Phone:
(323) 589-6181
Fax:
(323) 589-3463
e-mail:
www.barksdale.com
Operating Instructions
Dual Level Switch BLS3000
Art. no. 923-2159
Index A, 19.08.2016
Software-Version: 1.4 and higher
Specifications are subject to changes
without notice!
Barksdale GmbH
Dorn-Assenheimer Straße 27
D-61203 Reichelsheim
Phone:
+49 (6035) 949-0
Fax:
+49 (6035) 949-111 und 949-113
e-mail:
www.barksdale.de
 
 
 
 
 
 
 
 
 
 
 
 
1