- ページ 11
コンパス Astra A5040のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Astra A5040 14 ページ。 Fluxgate compass gyro
5
NMEA-0183 command Lisd.
The compass can be configured by sending various proprietary sentences to its NMEA-0183
input. Once configured, the compass will remember those settings every time it is
powered up.
Response:
When any of the following input sentences are received the A5040 will reply with an
'acknowledge' output sentence of the format:
$PATC,HCHDG,ACK<CR><LF>
except where noted to be different
5.1 AHD - Set heading:
$PATC,IIHDG,AHD,fff.f<CR><LF>
Forces the heading to a certain value by supplying an offset which is stored and used
Where f is in degrees with a valid range of 000.0 to 359.9
When f = 000.0 the result is the same as pressing switch 2
5.2 Set the internal filtering: ('damping')
$PATC,IIHDG,DHD,ddd.d<CR><LF>
Valid range for d is 0 to 100.0%
5.3 TXP - Set the Output update period in ms:
$PATC,IIHDG,TXP,uuuu<CR><LF>
note, minimum resolution – 10ms; Range: 100 to 2500 ms
Valid range is u=100 to 3000 milliseconds. This is limited by max. data rate of NMEA-0183
output at 4800 baud.
5.4 Start Auto-Calibration
$PATC,IIHDG,IAC<CR><LF>
Same as pressing Switch 1
5.5 Abort Auto-Calibration.
$PATC,IIHDG,XCL<CR><LF>
thereafter.
11