WARNING: Protect the water outlet from wind and do not operate in strong wind. If
the unit is installed in a windy area, water outlet could be often displaced.
3.1
OPERATION
-
The operation of the unit will depend on the control system installed, which is
not supplied with this unit.
A DMX/RDM controller with its respective software is required. We use these
ones to configure the channels and directions of DMX that we will use in our
equipment in a bidirectional way.
For the correct use of the pump, two different DMX channels are required.
Channel 1 is used to activate de pump:
-
0 - 127 : Pump OFF.
127 – 255: Pump ON
-
Channel 2 is used for the analog output. With this channel we can configure the
height of the water jet.
WARNING: The maximum work cycles of the pump are 60 starts/hour.
WARNING: Use the equipment only to pump water with the characteristics described
in section 1.2.
WARNING: Do not operate the pump until the water level is 25 cm above the highest
point of the pump.
3.2
MANTENIMIENTO
WARNING: Risk of dead due to electric shock. Disconnect the equipment from the
main power supply before performing any maintenance.
For the maintenance of the components made of stainless steel, see the manual
attached.
It is highly recommendable to activate the device at least once a week to check the
proper operation.
Clean the pre-filter of the pump at least once a week.
NOTE: The cleaning frequency of the pump pre-filter will depend on the conditions
in which the installation is.