照明器具 AmerTac Westek BL-BR33M-SWのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。AmerTac Westek BL-BR33M-SW 2 ページ。 Wireless motion activated under cabinet light
BL-BR33M-SW Owner's Manual
Location of Controls
1. Motion Sensor
2. Light Sensor
3. Motion Sensor Activation/
Manual On/Off Switch
4. 6 Super Bright LEDs
5. Battery Compartment*
OPERATING DIRECTIONS
Motion Sensor – Once batteries are installed:
Product includes an automatic light sensor that allows Motion Sensor to only operate at night or
in dark conditions. The light features an optional Motion Sensor which when activated will turn
the light ON automatically when motion is detected. The light will shut OFF automatically, after
30 or 60 seconds when no motion is detected. It detects motion approximate between 8.2 feet
(2.5m) and 11.5 feet (3.5M) of the motion sensor. To use this feature, simply slide the switch to the
desired location (30s / 60s).
OFF –Light will OFF.
ON – Motion sensor is inactive. Light will ON continuously.
30s – Light will turn OFF after 30 seconds if no motion is detected.
60s – Light will turn OFF after 60 seconds if no motion is detected.
MOUNTING INSTRUCTIONS
Magnetic Mounting (preferred)
The magnetic sections on the back of the light can be adjusted left to right so the corresponding
metal plates can be placed in the most ideal location for your installation.
Magnet option 1 - The metal plates come pre-drilled for easy front mounting on the desired
surface with included screws. Attached the fi rst plate to the overheads surface and check
location of second to make sure that sliding magnet will adhere to it.
Magnet option 2 - Remove protective cover from one side of the double-sided adhesive pad.
Place in center of the metal mounting plate. Do this for both metal-mounting plates. Place the
metal mounting plate with the adhesive pad onto the magnets located on the back side of
the light. Adhesive side placed away from the product (so it can stick into mounting position).
Do this for both metal-mounting plates. Remove second protective cover from adhesive tape
and place against desired surface. The metal mounting plate should be adhered to the desired
surface.
This is permanent tape that may cause damage if removed. Not recommended for use on
wallpaper or delicate surfaces.
Pulling on the light after the plates are properly installed should disconnect the metal mounting
plate from the magnets to allow for changing of batteries. The light should easily be able t o re
attached as the magnets and plates will draw to each other.
If you plan on using the light on a metal/magnetic surface, such as a cabinet, you may not need
to install the plates at all
Screw Mounting (optional)
1. Remove 2 metal plates & 2 3M Adhesive tapes from the 2 magnets on the back of the light.
2. Use Wall Anchors (not included) if securing to dry wall.
3. Measure two holes 6.75" (171 mm) apart. Drill two holes into mounting surface, insert wall
anchors (not included) and insert screws.
4. Leave screw heads out slightly so they can be inserted into the mounting holes located on
the back of the light.
5. Align and insert screw heads into mounting holes. Once inserted, slide the light onto the
screw heads to secure its position.
Limited Warranty
Under normal use and conditions, AmerTac provides to the original purchaser of this product a one year limited
express warranty that is set forth in the Limited Warranty stated in full at www.amertac.com/warranties. The
Limited Warranty is in lieu of all other express or implied warranties or liabilities subject to the exceptions
explained fully in the Limited Warranty on the website.
6. Magnets*
7. Slide Brackets*
8. Metal Plates*
9. 3M Adhesive Pads
**On back of unit
WIRELESS MOTION ACTIVATED
UNDER CABINET LIGHT
Product Dimensions:
Under Cabinet Light Size - 13.375" (H) x 2.25"(W) x 0.75"(D) / (340 mm x 56 mm x 19.3 mm)
INDOOR, DRY USE ONLY
BATTERY
--
Each Under Cabinet Light requires 3 AA batteries (not included).
INSERT/REPLACING THE BATTERIES
UNDER CABINET LIGHT – 3 AA batteries
If the LEDs appear to be dim this is an indication that the batteries need to be replaced.
-
Slide off the battery compartment.
-
Remove old batteries if replacing batteries.
-
Insert three new AA batteries.
-
Make sure to follow battery polarity guide when installing new batteries.
-
Replace battery compartment housing.
This product contains a button cell. If swallowed, it could cause severe injury or death in just 2
hours. Seek medical attention immediately.
SAFETY INFORMATION
Battery Precautions:
1. Use only the size and type of batteries specifi ed.
2. Always purchase the correct size and grade of battery most suitable for the intended use.
3. Be sure to follow the correct polarity when installing the batteries as indicated in the battery
compartment.
Reversed batteries may cause damage to the device.
4. Do not mix alkaline, standard (Carbon-Zinc), or rechargeable (Nickel Cadmium) batteries.
5. Replace all batteries of a set at the same time. Do not mix old and new batteries.
6. Clean the battery contacts and also those of the device prior to battery installation.
7. Do not dispose of batteries in fi re.
8. Remove batteries if consumed or if product is to be left unused for an extended period of
time.
250 Boulder Dr.
Breinigsville, PA 18031
610-336-1330
www.amertac.com
Made in China / Fabriqué en
Chine / Fabricado en China
© 2018 AmerTac™