- ページ 11
コントローラー Ametek Gemco 1996 Ram-SetのPDF インストレーション&メンテナンス・マニュアルをオンラインで閲覧またはダウンロードできます。Ametek Gemco 1996 Ram-Set 20 ページ。 Automatic press shut height controller
12. Drift Window: Establish an acceptable drift window. If the slide moves outside of
this window, the In Position relay denergizes. Typically 0.010 to 0.020 inch.
Note: In any cases where F - 3 - 9 - 1 - ENT is used, steps one (1) through eleven (11) will be erased from memory and
will have to be repeated.
The calibration steps are now completed and the system is ready for programming.
Chapter 3: Programming and Operating Instructions
Programming Dies:
1. Programming New Die #'s and Shut Height Values:
A. Select "Prog" mode on keyswitch
B. Depress F - 1 - ENT
C. Depress DIE # - Die code # - ENT
D. Enter shut height and depress ENT
E. *Optional Counter Balance Entry
*Optional Counter Balance Entry
Enter counter balance value (1-16) and depress ENT
The counter balance value will generate a (4) four binary output from the rear of the Ram-Set proportional to the pro-
grammed value. The binary output will interface to Gemco Series 2200 to automatically adjust the press counter balance.
Note: It is important that shut height value entered has been pre-tested with die in press prior to entry.
To program new die #'s and shut heights at this point, simply start at step C.
2. Operating in Auto Mode: This function allows the retrieval of existing programmed
dies and their associated shut heights.
A. Keyswitch in auto mode.
B. Depress DIE # - Die code # - ENT. The programmed optional counter balance will
now appear on the display for 3 seconds then it will display the shut height value.
C. Verify that shut height value and counter balance value correspond to the selected
die.
D. Depress ENT. This will enable the drive sequence. The drive sequence will remain
active until the shut height drive mechanism moves the slide to the programmed value.
E. Select "Standby" mode on keyswitch. The auto adjust sequence is now complete.
3. Operating in Jog Mode: This function allows the customer to manually jog the slide
using the Ram-Set keys.
A. Keyswitch in job mode.
B. Depress appropriate "Jog up" or "Jog down" key on unit for appropriate motion.
F
-
1
-
8
-
ENT
Installation and Maintenance Manual
-
Value
-
ENT
Chapter 2: Installation Instructions