- ページ 12

水ポンプ Akw M17 DigiPumpのPDF 設置および使用上の注意をオンラインで閲覧またはダウンロードできます。Akw M17 DigiPump 20 ページ。 Digipump

Pump Set Up

Pump Set Up
Control Button Description
Top Button = RUN (Sets shower stop run-on time)
Centre Button = TEST (Calibration)
Bottom Button = DELAY (Sets shower start delay to run)
Calibration
The AKW DigiPump allows for precise pump control of the shower waste water by calculating the amount of water
the shower is producing. It may be necessary to calibrate the pump once installation is complete (the pump may
be over or under pumping).
Before calibration, the correct flow sensor pulse rate must be set. See Pump Settings - Sensor type.
Run the shower at the expected normal flow rate. The pump must run at a speed which removes the same
amount of water as is flowing in.
Adjust the calibration value so the water level stays approximately the same. If the water level drops, decrease
the value on the display so the pump runs slower. If the water level rises, increase the value on the display so
the pump runs faster. When the value is set correctly, press the test button to store. The controller will then
return to its normal operating mode.
Timer Adjustment
With the pump in normal operating mode and the LED showing the run on time ...
Adjust Run on time. (the time the pump will run after the shower has stopped)
Press the RUN button: this will increase the time by 1 second, holding the button will increase the time
rapidly. Once the time reaches 99 it will roll over to 01.
Adjust Start Delay (the time before the pumps starts after the shower is operating)
Press the DELAY button: this will increase the time by 1 second, holding the button will increase the time
rapidly. Once the time reaches 99 it will roll over to 01.
12