Pump Settings
Pump Settings
When power is applied to the pump, the display will
briefly indicate the model and software version of
the pump (00-M11 : 01:M17 : 02:M20)
The pump will then enter standby mode.
In Standby Mode ...
The 'RUN' led will be lit, indicating mains voltage
present.
The display will indicate the 'run-on timer' setting
in seconds (factory default 20).
Setup
===================================
SENSOR TYPE (range 00 to 03) default 02
From standby ...
Press and hold the TEST button until the RUN led
flashes
00 : Relay
01 : 600 pulses per litre
02 : 1000 pulses per litre (default)
03 : 2200 pulses per litre
RUN button
Short press : increase (single)
Long press : increase (repeating)
DELAY Button
Short press : decrease (single)
Long press : decrease (repeating
Press the TEST button to save settings and enter
calibration mode
CALIBRATION (range 00 to 99) default 50
RUN button
Short press : increase (single)
Long press : increase (repeating)
DELAY Button
Short press : decrease (single)
Long press : decrease (repeating)
Press the TEST button to save settings and exit
calibration.
===================================
START DELAY (range 01 to 99) default 05 seconds
From standby ...
DELAY button
Short press : value single increment
Long press : value repeating increment
Press the RUN button to save settings and enter
standby mode.
===================================
RUN-ON TIME (range 01 to 99) default 20 seconds
From standby ...
RUN button
Short press : value single increment
Long press : value repeating increment
Pump is in standby mode.
===================================
TEST SEQUENCE
From standby ...
Press the 'TEST' button
The 'DELAY' led will start flashing
The display will indicate the 'start-delay timer'
setting in seconds (factory default 05).
The display will count down to zero
The pump will start
The display will indicate the time left to run in
seconds
When the display reaches zero the pump will revert
to standby mode.
This test can be carried out with or without water
present and also the sensor fitted or not.