景観照明 Dot-Spot brilliance RGBのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Dot-Spot brilliance RGB 20 ページ。 Recessed luminaire

Thank you / contents / intended use / installation
Thank you very much!
We are pleased that you decided to buy the dot-spot brilliance recessed luminaire!
dot-spot products are developed and manufactured according to very high quality guide-
lines. The high quality and long life of the products is an active contribution to resource
conservation and environmental protection.
The dot-spot brilliance is a compact recessed luminaire with a pivotable and turnable
10 W LED illuminant. The housing is entirely made of corrosion-resistant V4A stainless
steel. The ball mechanism guarantees an optimum heat transport from the LED towards
the floor housing. The integrated drive electronics has a temperature control which
reduces the power of the LED in the event of a risk of overheating.
At first, check the package contents
■ Brilliance recessed luminaire with clamping springs and pivotable LED illuminant
■ Floor sleeve
Intended use
The brilliance recessed luminaire serves for illuminating walls, faces, plants and such-
like from the ground as well as for creating light accents.
Following correct installation, the brilliance recessed luminaire is waterproof and insen-
nstallation, the brilliance recessed luminaire is waterproof and insen-
sitive against common weather and environmental influences.
In order to operate the brilliance recessed luminaire, depending on the number of
connected spots, a 24 V DC (12 V DC for the RGB version) power adapter with sufficient
output power is necessary. The recessed luminaire brilliance can be directly installed
in solid materials such as wood or stone, without using any floor sleeve. In case of an
installation in loose materials or concrete, we recommend using a floor sleeve.
In order to achieve a better illumination and to reduce the blinding effect, the illuminant
can be pivoted by up to 25 degrees and turned by 360 degrees.

Installation

During installation, the relative safety regulations have to be followed. The installation
may only be carried out by appropriately trained professionals.
11