- ページ 9

アクセサリー Baumer R600V.DAE0-11188367のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer R600V.DAE0-11188367 29 ページ。 Radar sensor for ground & crop distance (for general applications)
Baumer R600V.DAE0-11188367 にも: マニュアル (4 ページ)

Baumer R600V.DAE0-11188367 取扱説明書

2 Integration Guidance

CAUTION
Installation, mounting and adjustment of this product must only be
executed by skilled and authorized personnel.

2.1 Mechanical Integration

2.1.1

Mounting Direction, Blind-range

Mount the sensor with its centre axis approximately perpendicular to the direction of move-
ment and the ground. An angle may affect the measurement due to the Doppler Effect. In field
trials an angle of +/- 10° has been shown to be non-detrimental. Care should be taken to
evaluate influence of the Doppler Effect on the end-result. There is limited compensation for
the Doppler Effect in the software. The distance output is relative to the tip of the lens. A blind
range of 300mm must be considered. No (reliable) measurement is possible within the blind
range of the sensor, though strong targets may be detected. No targets above 6m are de-
tected.
Blind range
Fig 1
Mechanical Setup (for visualization only)
2.1.2

Mounting

A mounting plate with a flatness of better than 0.2mm per 100mm shall be used. Baumer
recommends soft steel as material to match specified mounting torque. For direct mounting
(thread in plate) Baumer recommends a thickness of the steel plate of at least 6mm. For
mounting on a thinner soft steel plates (≥3mm) flange nuts must be used instead.
R600V.DAE0_manual_1.5 (EN).docm
Last Update: 07 Jan 2021
Center axis
Manual R600V.DAE0 (EN)
Crop distance
Direction of movement
Ground distance
Page 9 of 29