6.9.9.
PROFIdrive parameter 979 sensor format
Readout of data block „Sensor Format". The data block informs on sensor parameters as sensor type,
programmed singleturn resolution, shift factor for G1_XIST1 and G1_XIST2 as well as the number of possible
turns (multiturn encoders). This information can also be called up individually utilizing the sub indexes.
The example shows how to call all elements of an encoder with a parameterized resolution of 8192
steps/revolution, revolution counter 65536 revs. (in this case 0xFFFF). Left-aligned display in G1_XIST1 by
shift factor =3.
DS_WRITE
DP-V1 Header
Called parameter Value
Function ID
ID
Index
Length
Data Unit - (write):
Byte #
0
1
2
3
4
5
6
7
8
9
Manual_ProfibusDPV2_BIDE_EN.docx
22.11.12
Permanent for DS_Write
Slot no.1 (E/A address telegram81)
47 = 0x2F
10 = 0x0A
Request Reference (example)
Request ID=0x01 Change ID=0x02
Shaft no. (0=whole device)
Number of parameters
Attribute = "Value"
Number of parameter elements
Prm_no hi: 979 = 0x03D3
Prm_no lo: 979 = 0x03D3
Subindex hi
Subindex lo
Example
0x5F
0x0200
0x2F
0x0A
Example
0xAA
0x01
0x00
0x01
0x10
0x06
0x03
0xD3
0x00
0x00
28/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany