6.9.11. I&M parameter 65000 block 0
I&M is a concept for uniform identification of field devices and is neither manufacturer nor industry-specific.
For this purpose, the field device provides particular information on an electronic product label.
Readout of block 0 of I&M functions (I&M0) is in line with PROFIBUS Identification & Maintenance Guideline
3502 and DPV2 encoder profile 3162. Data blocks I&M1 to I&M4 are not implemented.
I&M functions are accessed by Slot 0 or Slot 1 and index 255. Access to block I&M0 is by parameter number
65000 (0xFDE8).
Slot 0 of SIEMENS controls is addressed by the diagnosis address of the DP slave, in the example below
4093 (0x0FFD).
DS_WRITE
DP-V1 Header
Called parameter Value
Function ID
ID
Index
User data length
Data Unit - Call Header (read):
EXTENDED_
FUNCTION_NUM
reserved
IM_INDEX (hi)
IM_INDEX (lo)
DS_READ
DP-V1 Header
Called parameter Value
Function ID
ID
Index
Usere data length 68 = 0x44 max.
Data Unit - Call Header (read):
EXTENDED_
FUNCTION_NUM
reserved
IM_INDEX (hi)
IM_INDEX (lo)
Data Unit - Body (read):
Byte #
0...9
Header
10
I&M Block
11
12...31
32...47
48
49
50
51
Manual_ProfibusDPV2_BIDE_EN.docx
22.11.12
Permanent for DS_Write
Slot 0 (diagnosis address DP-Slave)
255 = 0xFF
4 = 0x04
0x08 permanent for CALL
ever 0x00
65000 = 0xFDE8
65000 = 0xFDE8
Permanent for DS_Read
Slot 0 (Diagnose-Adresse DP-Slave)
255 = 0xFF
0x08 permanent for CALL
ever 0x00
65000 = 0xFDE8
65000 = 0xFDE8
MANUFACTURER_ID
MANUFACTURER_ID
ORDER_ID (20)
SERIAL_NUMBER (16)
HARDWARE_REVISION
HARDWARE_REVISION
SOFTWARE_REVISION (*4)
SOFTWARE_REVISION
Example
0x5F
0x0FFD
0xFF
0x04
Example
0x08
0x00
0xFD
0xE8
Example
0x5E
0x0FFD
0xFF
0x40
Example
0x08
0x00
0xFD
0xE8
Example
0x00
0x01
0x2A
0x20
0x20
0x00
0x00
0x56 = 'V'
0x31 = '1'
31/41