- ページ 14

メディア・コンバーター Baumer Hubner Berlin PMG10のPDF 取付・取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer Hubner Berlin PMG10 32 ページ。 Absolute encoder
Baumer Hubner Berlin PMG10 にも: 取付・取扱説明書 (32 ページ), 取扱説明書 (44 ページ)

Baumer Hubner Berlin PMG10 取付・取扱説明書
MOUNTING
4.3
Maximum permissible mounting tolerance when the Baumer Hübner K 35 spring
disk coupling is used
Devices with a solid shaft should be driven through the Baumer Hübner K 35 spring disk
coupling (accessory), that can be pushed onto the shaft without axial loading�
i
The figure below shows the device with EURO flange B10, the same maximum per-
missible mounting tolerances are valid with the device with housing foot B3�
)
The device must be mounted on the drive with the least possible angular error and
parallel misalignment�
)
Risk of damaging the ball bearings
Coupling components must not be driven onto the shaft with improper force (e� g�
hammer impacts), because of the risk of damaging the ball bearings�
Admissible
parallel misalignment
* With insulated hub
All dimensions in millimeters, unless otherwise stated�
11/27
2-10
Admissible
angular error
MB253EN - 11173971, 19A2, Baumer_PMG10-DeviceNet_II_EN
Admissible
axial movement
±0�7 (±0�3*)