- ページ 13

メディア・コンバーター Baumer Hubner Berlin PMG10のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Baumer Hubner Berlin PMG10 44 ページ。 Absolute encoder
Baumer Hubner Berlin PMG10 にも: 取付・取扱説明書 (32 ページ), 取付・取扱説明書 (32 ページ)

Baumer Hubner Berlin PMG10 取扱説明書
Baumer Hübner
Ill. 4: Installing encoder, mounting device and coupling
1
Drive shaft
3
Attachment device (customized)
Tools
2.5 mm
n
n
Instruction:
a) Prior to installation, check the drive runout error and dimensions.
b) Mount the encoder in a way ensuring the electrical connection is protected against direct
water ingress.
c) Apply grease onto the drive shaft.
d) Mount the attachment device (customer-specific) to the drive using the fastening screws.
e) Push coupling onto the encoder shaft and tighten to the specified torque.
K35 permitted tightening torque:
Mt = 1 ±10 % Nm (plastic side)
Mt = 1.3 ±10 % Nm (metal side)
f) Mount the encoder using suitable screws, e.g. M6x16 mm (ISO 4017) onto the B10 flange of
drive or attachment device (customer-specific).
g) Fasten the coupling on the drive shaft.
K35 Permitted tightening torque:
Mt = 1 ±10 % Nm (plastic side)
Mt = 1.3 ±10 % Nm (metal side)
Observe the remarks in the data sheet and the coupling assembly instructions.
V1 | PMG10 & PMG10P SSI
1
2
10 mm
3
4
2
Mounting screw M6x16 mm for attach-
ment device (ISO 4017)
4
Coupling
Operating Manual
Installation
|
5
13