- ページ 7
ネットワーク・ハードウェア Amphenol Telect 009-7001-0104BのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Amphenol Telect 009-7001-0104B 15 ページ。 High-current demarcation panel
1.4.2 Installation Procedure
1. As shown in Fig. 2, remove the blank cover(s)
over the intended fuse holder position(s). The
unit can operate with one, two, three or four
fuse positions occupied.
NOTE: For safety, leave blank covers over all
unused positions.
Notice that "LINE" and "LOAD" appear above the
fuse positions. Remember: the LOAD end of the
fuses holders are always outboard — farthest
away — from the LED display. Meaning that
fuse holders will be installed "right" side up on
one side of the display and right side down on
the other.
ALERT! You can install fuse holders backwards. Observe the LINE and LOAD designations on the panel
vs. the designations on the fuse holders.
2. With the input power off, firmly install the circuit breakers or fuse holders in the panel. As shown in Fig. 3,
install the TFD fuse holders and bezel(s):
a. As directed in the illustration, make sure alarm connector on the breaker or fuse holder is straight prior
to installation.
b. Use the two screws supplied with each fuse holder to secure the holders to the bezel.
c. Attach the bezel to the chassis with a blank cover screw.
NOTE: Panel brackets are installed at the factory for flush mounting in a 19-inch rack. A pair of 23-inch
rack brackets are also included. Either pair of brackets can be moved or installed to extend front of panel
beyond the face of the rack in 1-inch (2.54 cm) increments.
WARNING! Failure to properly ground this equipment can create hazardous conditions to installation
personnel and to the equipment.
WARNING! Before connecting input power cables, make sure input power to panel is turned off.
High-Current
Demarcation Panel
Fig. 2: Removing blank covers
from model 009-7001-0104B