Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m)
of ice machine in accordance with local and national codes. Outdoor
installation is not recommended and will void warranty.
2.1
2.1
Installation site requirements
H_C1010A/W
requires 15A circuit,
1.50 mm
H_E1410A/W
requires 20A circuit,
4.00 mm
Electrical
➊
• H_C1010/1410(A/W)BS 208-230/60
• H_E1010/1410(A/W)BS 230/50
(H_E1010A/W requires 15A dedicated circuit 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
• This equipment is to be installed with adequate backflow protection to comply with applicable
federal, state, and local codes
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
➍
(3/4" Barb)
• Minimum 8" radius on silicone drain line. Drain line from the ice machine must have at least
1/4" per foot pitch (6,4mm/0,3m).
BIN • RIDE Technology
H_C1010A/W
NEMA
6-15
*
2
wire
‡
H_D710A
2
wire
NEMA
5-15
H_C1410A/W
NEMA
6-20
‡
➋
(3/8" push-in internal connection, 3/8" OD tubing required)
self-contained
➊
➋
➌
➍
• H_D710ABS 115/60
Requires dedicated 15A circuit.
wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm
2
➌
(1/4" FPT inlet, 1/4" FPT outlet)
Site preparation
2 ft. x 1" OD
silicone tubing
and ttings
provided
1/4" per foot
(6,4 mm per 0,3 m)
wire)
2
2