Follett HMC1410WBS Kurulum Talimatları Kılavuzu - Sayfa 5
Buz Yapıcı Follett HMC1410WBS için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Follett HMC1410WBS 17 sayfaları. Ice storage bins
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m)
of ice machine in accordance with local and national codes. Outdoor
installation is not recommended and will void warranty.
2.1
2.1
Installation site requirements
H_C1010A/W
requires 15A circuit,
1.50 mm
H_E1410A/W
requires 20A circuit,
4.00 mm
Electrical
➊
• H_C1010/1410(A/W)BS 208-230/60
• H_E1010/1410(A/W)BS 230/50
(H_E1010A/W requires 15A dedicated circuit 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
• This equipment is to be installed with adequate backflow protection to comply with applicable
federal, state, and local codes
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
➍
(3/4" Barb)
• Minimum 8" radius on silicone drain line. Drain line from the ice machine must have at least
1/4" per foot pitch (6,4mm/0,3m).
BIN • RIDE Technology
H_C1010A/W
NEMA
6-15
*
2
wire
‡
H_D710A
2
wire
NEMA
5-15
H_C1410A/W
NEMA
6-20
‡
➋
(3/8" push-in internal connection, 3/8" OD tubing required)
self-contained
➊
➋
➌
➍
• H_D710ABS 115/60
Requires dedicated 15A circuit.
wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm
2
➌
(1/4" FPT inlet, 1/4" FPT outlet)
Site preparation
2 ft. x 1" OD
silicone tubing
and ttings
provided
1/4" per foot
(6,4 mm per 0,3 m)
wire)
2
2
5