- ページ 12

冷凍庫 Follett FZR4-ADAのPDF 設置、操作、サービスマニュアルをオンラインで閲覧またはダウンロードできます。Follett FZR4-ADA 20 ページ。 Undercounter freezer
Follett FZR4-ADA にも: 設置、操作、サービスマニュアル (20 ページ)

Follett FZR4-ADA 設置、操作、サービスマニュアル

Controller Replacement

1. Shut down unit by moving rocker switch on the lower front panel to the OFF position and removing power
cord from receptacle.
2. Remove 6 screws from front panel and slide panel forward to access back of controller.
3. Disconnect front panel and wiring harness from freezer at the 3-, 4-, and 5-pin connectors and door heater
connector to simplify replacement.
4. Push in on center of side brackets (on controller) to release and slide brackets back and off controller.
5. Push controller and wires out through front of front panel.
6. Using wiring diagram on next page (and attached to front panel) as a guide, remove wires one at a time
from back of existing controller and connect to corresponding terminals on replacement controller.
7.
Insert replacement controller back through front of panel.
8. Slide brackets onto sides of controller and push against back of front panel.
9. Reconnect 3-, 4-, and 5-pin connectors of wiring harness to freezer.
10. Keeping wiring clear of condenser, replace front panel.
11. Restore power and test operation. Reprogram replacement controller if necessary.
12