AS5600-SO_RD_ST
Operation Manual
The magnet is already aligned to get AGC values in the middle of the AGC range.
Note: If the magnetic field seen by the AS5600 would be below 8mT, the output would be switched
off and permanent angle programming would not be possible.
2.4 Electrical Setup
The reference module is many used in following configurations in 5V or in 3.3V mode.:
2.4.1 3-Wire Mode
In this mode, the power supply and the output pin of the reference module are connected. To
program a custom angular output range, short R4 using a 0R resistor to enable the programming
option B. Follow the step-by-step instructions in the AS5600 datasheet to program the device.
Figure 3:
Using the board in 3-Wire Mode
µC
Analog or PWM IN
2
2.4.2 I
C Mode
Using the I2C Interface, all functions of the AS5600 can be configured and permanently
programmed. Additionally the output and a raw angle (unmodified value) can be read from the
output registers.
Figure 4:
Using the reference module in I2C Mode
µC
www.ams.com
+
-
+
-
SDA
SCL
Revision 1.1 / 30.06.2014