Figure 5: EH244 Firmware Update Tab
Important Notes
EAS Notes
When the EH244 is running in an EAS mode, the
emergency alert state is entered when the two termi-
nals on the rear panel labeled EAS are connected
together via an external contact closure. EAS re-
ceivers should provide this contact closure output,
which will be wired to the terminal block on the rear
of the EH244.
IMPORTANT NOTES
If the EH244 is using the Slot 6 or Slot 6 +
SCTE 18 EAS modes, ensure that the bit rates of
the SDE24EAS encoder's two output channels are at
least as low as all of the other encoders in the entire
system. This guarantees that, during an EAS event,
the output bit-rates of the system are not exceeded
by the replacement video channels.