- ページ 19
インバーター Advanced Energy Industries RFX 600のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Advanced Energy Industries RFX 600 20 ページ。 Advanced energy generator
FIRST TIME OPERATION
Unpacking
DO NOT APPLY POWER TO THE UNIT BEFORE FOLLOWING THIS
PROCEDURE:
Unpack and inspect your power supply carefully.
Check for
obvious physical damage.
Remove the top cover (6 phillips screws).
Inspect the
plexiglass shield for signs of physical damage and if none,
replace cover and proceed to the connection section.
Start-up Procedure
1.
Connect output connector to ATX.
2.
Connect input power (115 VAC or 240 VAC).
3.
Turn on breaker at rear of unit.
Fan will turn on.
4.
Press power push button on the front panel.
Both
displays will turn on, as well as the power LED, RF OFF
LED, and any control button that is activated.
5.
To set output level, select regulation mode (FWDPWR, DC
BIAS, or LOAD PWR).
Press SETPOINT push button and hold
while adjusting power level.
Observe left display for
desired value.
Release button.
CAUTION!
The next step will cause RF to be present at the output
connector.
Take appropriate steps to prevent electrical
shock.
6.
To enable output, press RF on.
The main contactor will
close and the output light will come on.
The SETPOINT
light will continue to flash until the output is
delivering its preset level.
20