- ページ 6

ボイラー Drazice OKC 100 NTRのPDF 操作および設置マニュアルをオンラインで閲覧またはダウンロードできます。Drazice OKC 100 NTR 20 ページ。 Tank-type water heaters for vertical mounting
Drazice OKC 100 NTR にも: 操作および設置マニュアル (17 ページ), 操作および設置マニュアル (12 ページ), 操作および設置マニュアル (20 ページ), 操作および設置マニュアル (18 ページ), 操作および設置マニュアル (20 ページ), 操作および設置マニュアル (18 ページ)

Drazice OKC 100 NTR 操作および設置マニュアル

1.3 DESIGN AND GENERAL HEATER DIMENSIONS

The heater tank is made of a steel plate and tested by 0.9 MPa overpressure. The inside of the receptacle is
enamelled. A flange is welded onto the bottom of the tank with a flange lid screwed to it. A sealing ring is
inserted between the flange lid and the flange. Thermowells for placing a heating element and sensors of
regulation thermostat and safety fuse are located in the flange lid. Anode rod is mounted on M8 nut. The
water reservoir is insulated by means of polyurethane foam. Electric wiring is placed underneath the
plastic removable cover. The temperature of water can be set using the thermostat. In combined versions,
a heat exchanger is welded in the pressure tank. The heat exchanger is only intended for the heating
circuit.
- 6 -