- Do not install on HOT WATER. Temperature of water supply to the
filter system must be between minimum of 40°F and maximum of
90°F.
- The assembly can stand up in the sink cabinet or can be hung on
screws.
- Use PTFE (Teflon) tape for the fittings and do not overtighten.
COLOR CODE FOR TUBING
Use the color-coded tubing to make connections as follows:
A. Red tubing connects water supply adapter to inlet side of the
assembly
B. Blue tubing connects the faucet to the outlet side of assembly
Feed Water Supply
1. Close the cold-water supply valve under the sink.
2. Unscrew the flexible tubing from the supply valve that connects to
the COLD-water riser.
NOTE: If the cold water shut-off valve fails to turn off the water,
house water supply can be turned off at the main water supply.
3. Disconnect the threaded nut at the
connection, and with the flat washer in
place, thread the feed water supply adapter
onto the connection and tighten. Connect
the Red Tube to the water supply adapter
with the treaded nut and tighten. DO NOT
OVER TIGHTEN.
4. Thread the needle valve into the adapter
tightly and turn the handle clockwise all the
way in. Open the main water supply valve
and several house faucets to purge air from
the system. Close faucets when water runs
smoothly. Turn on cold water supply to the
sink faucet and check for leaks