- ページ 5
バッテリーチャージャー Formica IntentekのPDF テクニカルマニュアル 使用とケア、保証、およびインストールマニュアルをオンラインで閲覧またはダウンロードできます。Formica Intentek 17 ページ。 Wireless charging surface
INTENTEK
WIRELESS CHARGING SURFACE
™
TECHINCAL GUIDE USE & CARE, WARRANTY, AND INSTALLATON GUIDE
Oxivir
Tb and wipes
™
Accel
TB and wipes
®
Peroxide Multi Surface Cleaner and Disinfectant
Suretouch
®
Oxy-Team
Disinfectant Cleaner
™
ORDINARY CLEANING OF UNDERSIDE OF TABLE/
COUNTER
Should cleaning on the underside of the counter/table be needed,
avoid exposing the electronics to any liquids.
FABRICATION & INSTALLATION
FABRICATION & INSTALLATION RELATED SAFETY
1. All points in Customer Safety above also pertain to fabrication
and installation safety.
2. Fabricators and installers must follow all OSHA/ National Electric
Code /UL Standards as required by installation location or
customer.
3. Do not power the electronics until fully assembled into a table or
top. Make all connections to the Intentek
before applying power.
4. Intentek
Electronics AC Adapter or equivalent must be used.
™
Formica Group does not recommend or warranty hardwiring.
5. Do not install finished table or top while electronics are powered.
6. Always use recommended wire to connect electronics modules.
7. Always cover wiring underneath table/counter.
INSPECTION
Inspect all materials at the time they are received to ensure all
components are free of damage and/or visible defects. Do not
assemble materials with known defects. It is the responsibility of the
customer/fabricator/installer to inspect materials before installation.
Before fabrication, confirm that Computer-Aided Design (CAD) files
are available.
STORAGE CONDITIONS
The optimal conditions for storage are 50 – 90°F (10 – 32°C) and
30% – 65% humidity. Keep materials free from moisture, dust, and
impact. The material should never be stored in contact with the floor
or an outside wall.
Laminate sheets and backers have been shipped in a way to protect
both materials. Formica Group recommends that they are stored
in the way they are shipped in order to continue to protect until
installation.
Due to delicate nature of the coils embedded in the underside of the
decorative laminate, do not slide the back of the laminate against
another surface. Keep coils covered with the provided
covering until cavity has been cut with CNC.
FTB-0918 | Rev 2 | 6/20
ACCLIMATION CONDITIONS
Prior to fabrication, allow laminate sheet, backer, and substrate to
acclimate for at least 48 hours at the same ambient conditions. The
optimal conditions for acclimation are 50 – 90°F (10 – 32°C) and
30% – 65% humidity.
FABRICATION CONDITIONS
Laminate sheets, backers, substrate surfaces, and electronic
components must be dry, clean and free of all grease, dust, and
foreign matter. The optimal conditions for fabrication are
50 – 90°F (10 – 32°C) and 30% – 65% humidity.
INTENTEK
APPLIED TO
1. Medium Density Fiberboard (MDF)
2. Particleboard
3. Hardwood Faced Veneer Core Plywood, also known as
TOOLS & MATERIALS SOLD
BY FORMICA GROUP
•
•
Electronics Module
™
•
•
•
•
ADDITIONAL TOOLS & MATERIALS NEEDED
•
WIRELESS CHARGING SURFACES MAY BE
™
Grade A Faced Plywood
Intentek
Laminate in the specified quantity
™
Intentek
Laminate backer in the specified quantity
™
Intentek
Electronics Universal AC power adapter in the
™
specified quantity
Intentek
Electronics module in the specified quantity
™
Test Receiver {Provided to Fabricator Partners Only}
Test Receiver manual {Provided to Fabricator Partners Only}
Personal Protective Equipment (PPE), examples:
• Eye protection
• Dust mask
• Gloves
• Hearing protection as needed
Formica Group Technical Guide
| 5