However, it is not necessary to purge when the temperature is higher than 750°C. Air pipe or
gas pipe connected with burner should be tight enough with no leakage, also the periodically
check air or fuel nozzles of the burners to prevent to be blocked by dust, slag or other materials.
ATTENTION:DANGER OF BEEN BURNT
When burner in operation, combustion is severe, so the burner must be fixed. Hoses or cables
in area of the combustion system must be suitable for high temperature, to prevent high
temperature failure or cause safety accidents. Burners should be periodically inspected and
cleaned. Copper wire brush may be used, if necessary, to clean burner head. The burner system
should be checked twice a year for safety operation.

4. Configuration

FFO50 FlexFire® Oxygen Fuel Burner configuration as Fig 1 shown.it is made up by gas and
oxygen inlet, adjustment device and fix device.
Figure 1:FFO50 FlexFire® Oxygen Fuel burner Standard configuration

5. Installation

1. Fix burner bracket with bolts, gasket and washers to make sure the horizontal plate is level,
burner and burner block shown as Fig 2 shown.
2. Fix burner to burner bracket with clamp attached tightly.
3. Connect hose of the down comer to burner with quick connectors.