6.10
Removing the Ki03 belt
Protective gloves must be worn
1.
Remove the worktop.
2.
Remove the rear panel.
3.
Pull off the electrical connections F for the heater and
temperature controller.
4.
Remove the bottom process air duct cover.
5.
Remove the process air impeller.
6.
Detach the belt over the drum.
7.
Remove the two top screws A on the process air duct.
8.
Thread the belt between the process air duct and housing.
9.
Insert and tighten the two screws A you removed earlier.
10.
Remove the two bottom screws B on the process air duct.
11.
Press the duct back and thread the belt between the housing
and process air duct
12.
Remove the belt.
Stretch belt before assembly!
113_58300000104082_ara_en_h.doc – 19.03.07
(see step
8).
Step 3