- ページ 3

ボイスレコーダー ANDERSON-NEGELE AV-9900のPDF 基本設定マニュアルをオンラインで閲覧またはダウンロードできます。ANDERSON-NEGELE AV-9900 5 ページ。 Htst recorder controller

3
16. Scroll to Limit Low – Low end of input range (HWC, CPR, SFLR)
a.
Press MOD to get cursor
b.
Use up/down arrows to change value if needed
c.
Press ENTER to save
17. Scroll to Limit High – High end of input range (HWC, CPR, SFLR)
a.
Press MOD
b.
Use up/down arrows to change value if needed
c.
Press ENTER to save
18. Repeat for all Inputs
19. Press REST back to main screen
1.
Scroll to Configuration
2.
Press down
3.
Scroll to Recording Pens
4.
Press down to STLR INPUT/EVENT
5.
Press ENTER
6.
Scroll to INP Limit Zone Low (inside ring of chart)
a.
Press MOD
b.
Use up/down arrows to change value if needed
c.
Press ENTER to save
7.
Scroll to INP Limit Zone High (outside ring of chart)
a.
Press MOD
b.
Use up/down arrows to change value if needed
c.
Press ENTER to save
8.
***For SFLR only Scroll to INP Zone High Division***
a.
Must be set to 40
9.
Repeat steps for all available inputs
10. Press RESET back to main screen
Programming 4-20mA Outputs
1.
Scroll to Function Setup
2.
Press Down
3.
Select the input you are trying to assign (make sure it is flashing and press enter or press
the soft key under the input)
4.
Scroll to INP Transmit to Current Output
5.
Press MOD to get cursor
a.
a. Use up/down arrows to change
i.
i. 1 = output #1
ii.
ii. 2 = output #2
b.
b. Press ENTER to save
Programming Inputs
Programming Recording Pens
(Printed Chart Scales)
AV-9900 HTST Recorder Controller
(cont'd)