- ページ 15
換気フード Electrolux DD9691-MのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。Electrolux DD9691-M 20 ページ。 Built-in- flat-screen fume extractor hood
• This filter cannot be washed or regenerated. It must be replaced when the C appears on the
display or at least once every 4 months.
Activation of the alarm signal
• In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
• Switch off the hood and the lights.
• Disconnect the hood from the mains supply.
• When restoring the connection press and hold C-key.
• When releasing the key two rotating rectangles appear on the display.
• Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly:
• 2 flashes with C - charcoal filter saturation alarm ACTIVATED
• 1 flash with C - charcoal filter saturation alarm DEACTIVATED.
REPLACING THE CHARCOAL FILTER
Reset of the alarm signal
• Switch off the hood and the lighting.
• Press the D-key until the display is unlit.
Replacing of the filter
• Open the comfort panels pulling them downwards.
• Remove the metal grease filters.
• Remove the saturated charcoal filter by releasing the fixing
hooks
• Fit the new filter and fasten it in its correct position.
• Put the metal grease filters in their seats.
• Close the comfort panels.
EN
Charcoal filter (recycling version)
2 25