除湿機 Dri-Eaz DrizAir 1200のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Dri-Eaz DrizAir 1200 4 ページ。 110v/50hz portable dehumidifier
Dri-Eaz DrizAir 1200 にも: オーナーズマニュアル (13 ページ), オーナーズマニュアル (5 ページ), オーナーズマニュアル (18 ページ), オーナーズマニュアル (2 ページ), オーナーズマニュアル (19 ページ)

Dri-Eaz DrizAir 1200 オーナーズマニュアル
SPECIFICATIONS
Model
Water Removal, maximum
Water Removal, AHAM
(21ºC, 60% Rh)
Airflow
Use Weight
Dimensions
Operating range
Safety Listings
Filter
Defrost
Pump
Refrigerant
Compressor
One dehumidifier will dry the air in APPROXIMATELY the size of the following
drying chamber or room(s) with a standard ceiling.
Soaking wet
Moderately wet
Mostly dry
Specifications are subject to change without notice. Some values are approximate.
TROUBLESHOOTING
In COLUMN 3, "FS" or Field Solutions can be handled by the technician in the field. Others solutions should be handled by a repair technician –
an "AST" or Authorized Service Technician.
WARNING: All the service procedures below should be executed with the power turned off, i.e. unplugged.
PROBLEM
Unit does not operate
Compressor will not start
Blower wheel not turning
Dehumidifier operating
but room not dry
Only partial frost
or moisture on coils
No moisture
or frost on coils
Unit continuously in defrost
Unit does not defrost
(heavy frost or ice
persists over several hours)
Unit collects little water
Pump does not function
FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIBUTOR,
or the Dri-Eaz Service Department at (360) 757-7776 in the US, or (01908) 611211 in the UK.
Copyright 2000, 2002, Dri-Eaz Products, Inc.
DRIZAIR 1200
DRIZAIR 2000 LG
58 liters
30 liters
385 m2/hr
36 kg
83x50x50 cm
103x61x57 cm
0° - 38° C
CE
Foam or Paper
Hot Gas Bypass
Hot Gas Bypass
Centrifugal
R-417A
6,670 BTU Rotary
10,535 BTU Rotary
30 m2
45 m2
90 m2
CAUSE
No power to machine
Switch not turned on
Unit needs 5 minutes before re-start
Overload preventing start up
Faulty or broken wire
Defective relay
Compressor not running
Obstructed blower
Loose blower wheel set screw
Loose or broken wire
Burned out fan motor
Not enough time to dry
Poor air movement
Excessive air infiltration
Possible leak in system
Low charge in system
Possible leak in system
Capillary tubing damaged
Compressor not running
Room temperature too low
Defective control assembly
Defective bypass relay valve
Defective sensor
Defective control assembly
Defective bypass relay valve
Room air too dry
Room temperature too low
Airflow through unit restricted
Stuck float valve
71 liters
42 liters
513 m2/hr
60 kg
0° - 38° C
CE
Foam
Centrifugal
R-417A
50 m2
75 m2
150 m2
See
above
SOLUTION
FS
Plug in the unit; check power at outlet
FS
Turn on the switch
FS
Switch off unit, wait 5 minutes before starting
FS
Reduce room temperature below 100° F (38° C)
AST
Replace or repair broken/loose wire
AST
Check relay with volt/amp meter
AST
Contact distributor or Dri-Eaz Products
FS
Remove obstruction
FS
Tighten set screw
AST
Replace broken wire
AST
Replace fan motor
FS
Allow more time for drying
FS
Increase air movement with TurboDryers
FS
Reduce airflow into the area being dried
AST
Check for leak with gas leak detector
AST
Repair and recharge system
AST
Check for leak with gas leak detector
AST
Look for damage, replace tubing
AST
Contact distributor or Dri-Eaz Products
FS
Increase room temperature
AST
Replace control assembly
AST
Replace bypass valve
AST
Replace sensor
AST
Replace control assembly
AST
Replace bypass valve
FS
Check humidity with a hygrometer
FS
Increase the room temperature
FS
Increase airflow; clean filter and coils
FS
Clean float valve shaft