- ページ 10

浄水器 Atlantic Ultraviolet 10-0508BのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Atlantic Ultraviolet 10-0508B 20 ページ。 Germicidal ultraviolet water purifiers
Atlantic Ultraviolet 10-0508B にも: オーナーズマニュアル (16 ページ)

G
K
I
ROUNDING
IT
NSTALLATION
USING BALLAST NO
10. Ground Kits are shipped with each MINIPURE
10-0504A and is used to permanently connect a ground wire from the water purifier chamber to a known good ground.
We recommend checking with local codes or a licensed electrician in your area to determine the best grounding point to
attach the ground kit for your installation. An electrician can also measure the resistance between the water pipe and an
electrical outlet ground to insure your ground selection is correct.
Placement: Select a location that is visible as well as accessible. Connect the ground strap to a known good ground or a
water pipe that is metallic, with no intervening plastic fittings between it and the power ground.
Installation: Once a proper ground point has been determined, fasten the ground to the water purifier chamber as shown and
described below.
If you receive a 230v 50/60Hz water purifier, or ballast for a water purifier using ballast no. 10-0504A and a grounding kit is
not present in the carton please contact the factory with your order information and we will send you the correct grounding
kit for your application.
T
R
OOLS
EQUIRED
7/16" Wrench
10mm Wrench or Universal Pliers
Continuity Tester
Step 11 - Wrap Strap Tight Around Pipe
Step 14 - Install Nut on Stud
WARNING: To insure proper operation and safety of your water purifier, your unit must be
grounded to a known good ground.
10
: MIN-6
.10-0504A
Step 12 - Insert Bolt Through Both
Copper Holes & Tighten using a 7/16"
Wrench
Step 15 - Slide Ring Terminal Wire
Assembly onto Stud & Lock Washer
over Ring
MIN-9 230
50/60H
AND
V
®
Model MIN-6 and MIN-9 230v 50/60Hz water purifier using ballast
Z
Step 13 - Insert Wire Into Hole & Install
Bolt / Tighten Bolt against Wire using
10mm Wrench, Ensure all is Secure
Step 16 - Install Nut on Stud against
Washer & Tighten with 7/16" Wrench